Весовой терминал LCC-II

Vishay Precision Group
Цена
Склад:
  • Ten calibration registers with 10 point linearization curves
  • BLH Quick Cal, 10 point deadload, or 10 point data sheet calibration available for each register
  • An additional register reads live load cell mV/V
  • Display .Hold. function
  • Optional 16 bit analog output configurable for each register
  • Peak and valley capability for each register

Description

The LCc-II load cell calibration indicator uses microprocessor technology to store ten individual, ten point linearized, load cell calibration curves. This capability allows this device to be used as a calibration force measurement indicator with up to ten different load cells. In addition, the LCc is pre-configured at the factory to read actual load cell mV/V outputs for use as a measurement standard with virtually any load cell or other Wheatstone bridge based transducer. For portability, a ruggedized enclosure with transducer selection switch and carry handle is provided. If documentation is required, units have a serial printer communication interface. Hot key displays provide instant access to cell mV/V output, peak, valley, zero, and tare values. To check calibration, three standard values are switch selectable along with a fourth provision for a user supplied resistor. Rear panel tension or compression selection reverses polarity if needed. Signal communication is available in 16 bit analog output and RS-422/485 digital formats. The RS-422 signal can be used for printouts or a full, bi-directional PC interface. When combined with master (NIST calibrated) load cells, the LCc-II becomes a highly accurate system for checking and calibrating other force and weight measurement equipment.

К товару "Весовой терминал LCC-II" еще не поступало отзывов.
Оставить отзыв
Весовой терминал LCC-II Ten calibration registers with 10 point linearization curves BLH Quick Cal, 10 point deadload, or 10 point data sheet calibration available for each register An additional register reads live load cell mV/V Display .Hold. function Optional 16 bit analog output configurable for each register Peak and valley capability for each registerDescriptionThe LCc-II load cell calibration indicator uses microprocessor technology to store ten individual, ten point linearized, load cell calibration curves. This capability allows this device to be used as a calibration force measurement indicator with up to ten different load cells. In addition, the LCc is pre-configured at the factory to read actual load cell mV/V outputs for use as a measurement standard with virtually any load cell or other Wheatstone bridge based transducer. For portability, a ruggedized enclosure with transducer selection switch and carry handle is provided. If documentation is required, units have a serial printer communication interface. Hot key displays provide instant access to cell mV/V output, peak, valley, zero, and tare values. To check calibration, three standard values are switch selectable along with a fourth provision for a user supplied resistor. Rear panel tension or compression selection reverses polarity if needed. Signal communication is available in 16 bit analog output and RS-422/485 digital formats. The RS-422 signal can be used for printouts or a full, bi-directional PC interface. When combined with master (NIST calibrated) load cells, the LCc-II becomes a highly accurate system for checking and calibrating other force and weight measurement equipment.